Cabinet air conditioner

Cabinet air conditioning unit

Content Introduction

Beautiful appearance

The panel is made of high-pressure polyurethane foam insulation board, and its appearance is made of high-quality color steel plate. This panel features high strength, excellent sound insulation and heat preservation performance, as well as cleanliness and beauty.

Reasonable structure

The patented technology of the crimping and sealing insulation board structure without cold bridge is adopted. The process is advanced, the air leakage rate of the unit is low, cold bridge and frosting are eliminated, energy saving is significant, and maintenance is convenient.

Reliable data

The unit has been calculated by professional selection software and undergone professional tests to ensure the authenticity of the data, enabling users to make more accurate selections and avoid unnecessary waste and deficiencies.

High heat transfer efficiency

High-quality thin-walled copper tubes and corrugated new aluminum fins are adopted, and the tubes are mechanically expanded to ensure a tight fit between the copper tubes and the fins, significantly reducing the heat transfer thermal resistance and enabling the unit to achieve the maximum heat transfer performance.

Low operating noise

The adoption of high-quality low-noise motors and the application of low-speed and high-volume fans make the operation of the unit more quiet and with lower noise.

Flexible selection and configuration

Functions such as heating, humidification and high-end purifiers can be added according to customer requirements.

Performance Parameter Table 1

Return air condition

Model Air volume Cooling capacity  KW Calorific value  KW Water flow rate  L/S Water resistance  Kpa Outside the aircraft
Static pressure
Motor power Chilled water
Pipe diameter
Condensate water
Pipe diameter
Row 4 Row 6 Row 8 Row 4 Row 6 Row 8 Row 4 Row 6 Row 8 Row 4 Row 6 Row 8 Row 4 Row 6 Row 8
G-03 3000 17.7  21.3  24.8  27.4  31.5  34.3  0.94  1.13  1.32  14.7  26.1  150  0.55  0.75  0.75  DN32 DN25
G-04 4000  21.6  29.1  33.6  35  42.4  46  1.15  1.54  1.78  23.8  41.2  180  1.1  1.1  1.1  DN40 DN25
G-055000 28  37  42.5  44.6  53.4  57.8  1.48  1.96  2.25  17  42.7  73.1  180  1.5  1.5  1.5  DN40 DN25
G-06 6000  34.1  44.9  51.3  53.7  64.4  69.5  1.81  2.38  2.72  21  53.3  90.6  180  1.5  1.5  1.5  DN40 DN25
G-07 7000 40.6  53  58.8  63.2  75.5  80.5  2.15  2.81  3.11  33  81  41.8  220  1.5  2.2  2.2  DN50 DN25
G-08 8000  46.6  606 67.3  72.5  86.4  92.1  2.47  3.21  3.57  37  89.3  46.3  220  2.2  2.2  2.2  DN50 DN25
G-09 9000 52.9  98.6  76  82.1  97.4  103.8  2.8  3.63  4.03  41  98.3  50.7  260  2.2  DN50 DN25
G-10 10000  59.3  74  84.9  91.5  106.8  115.5  3.14  3.92  4.5  54.6  39.3  67.1  260  DN50 DN25
G-1414000 85.4  94.1  120.5  130.4  149.8  162.7  4.53  4.98  6.38  79.4  45.8  95  300  5.5  5.5  DN65 DN25
G-18 18000  07.4  33.7|1 53.21  65.41  92.52  08.1  5.68  7.08  8.12  66.8  48  81.7  350  5.5  7.5  7.5  DN65 DN32
G-2424000 44.3  79.5  205  221  257.3  277.7  7.63  9.5  10.85  98.2  70.4  119  400  11  11  11  DN65 DN32
G-30 30000  175.3  227.4  254.5  272.5  323.6  346.3  9.28  12  13.48  43.9  105  76.9  400  11  11  11  DN65 DN32
G-35 35000  201.6  259.9  297.6  315.5  373.9  404.2  10  138 5.75  46.4  55.2  93.8  400  11  15  15  DN80 DN32
G-40 40000  236.2  298.2  340.8  364.9  428  4,623 12.5  158 803 63.9  65.4  110.4  400  15  15  15  DN80 DN32

1、The standard cooling capacity operating conditions of the unit are as follows: the dry bulb temperature of the inlet air is 27℃, the wet bulb temperature is 19.5℃, the inlet water temperature is 7℃, and the temperature difference between the inlet and outlet water is 5℃.
2.、Standard heat supply conditions of the unit: inlet air dry bulb temperature 21℃, inlet water temperature 60℃, water supply volume is the same as the cooling capacity condition.
3、The above parameters are standard model parameters. If you have any special requirements, we will provide you with a specially designed one.
Performance Parameters Table 2

Return air condition

Model Air volume Cooling capacity KW Calorific value  KW Water flow rate  L/S Water resistance Kpa Outside the aircraft
Static pressure
Motor power Chilled water
Pipe diameter
Condensate water
Pipe diameter
Row 4 Row 6 Row 8 Row 4 Row 6 Row 8 Row 4 Row 6 Row 8 Row 4 Row 6 Row 8 Row 4 Row 6 Row 8
G-03 3000  36.8  47.6  53.4  39.6  45.1  48  1.95  2.53  2.83  56.2  63.9  104.8  150  0.55  0.75  0.75  Dn32 Dn25
G-04 4000  50.4  64.4  70.3  52  60.4  63.8  2.67  3.41  3.73  42.8  101  50.2  180  1.1  1.1  1.1  DN40 DN25
G-05 5000  64.2  78.9  88.7  65.3  74.9  79.9  3.40  4.18  4.70  77  53.6  88.6  180  1.5  1.5  1.5  DN40 DN25
G-06 6000  77.9  95.4  106.9  78.8  90.2  96.1  4.13  5.05  5.67  96.1  66.5  109.4  180  1.5  1.5  1.5  DN40 DN25
G-07 7000  88.0  112.4  123.8  90.7  105.6  111.8  4.66  5.95  6.55  42.9  100  71.1  220  1.5  2.2  2.2  DN50 DN25
G-08 8000  100.8  128.7  41.6  103.7  20.7  127.8  5.33  6.82  7.50  47.4  111  78.5  220  2.2  2.2  2.2  DN50 DN25
G-09 9000  114.3  142.3  159.8  117.1  135  144  6.05  7.53  8.47  52.5  52.3  86.1  260  2.2  DN50 DN25
G-10 10000  128.  159.  1178.  2|130 5150.  3160.1  6.78  8.43  9.43  69.8  69.3  113.2  260  DN50 DN25
G-14 14000  184.2  226.8  249.8  185.1  212  224.4  9.75  12.00  13.23  101  98.6  84.1  300  5.5  5.5  DN65 DN25
G-18 18000  231.3  287.2  317.9  235.2  270.7  287.3  2.27  15.20  6.83  85.4  84.3  72.4  350  5.5  7.5  7.5  DN65 DN32
G-24 24000  301.0  384.6  421.1  310  361.1  382.1  15.93  20.37  22.30  52.8  123  62.3  400  11  11  11  DN65 DN32
G-30 30000  383.6  479.0  531.2  390.7  451  479.  20.30  25.37  28.13  79.5  98.5  92.2  400  11  11  11  DN65 DN32
G-35 35000  449.4  560.3  621.0  456.2  526.4  559.2  23.80  29.67  32.92  97.7  117  112.8  400  11  15  15  DN80 DN32
G-40 40000  515.5  641.9  710.9  521.9  601.9 
636,326
7,303 4,003 7.67  115  138  132.7  400  15  15  15  Dn80 Dn32

1、The standard cooling capacity operating conditions of the unit are as follows: the dry bulb temperature of the inlet air is 35℃, the wet bulb temperature is 28℃, the inlet water temperature is 7℃, and the temperature difference between the inlet and outlet water is 5℃.
2、Standard heat supply conditions of the unit: inlet air dry bulb temperature 7℃, inlet water temperature 60℃, water supply volume is the same as the cooling capacity condition.
3、The above parameters are standard model parameters. If you have any special requirements, we will provide you with a specially designed one.